Locator settings and survey measurements

Follow Avatar Anthony Caplin
Updated : Created :
In this article

Check locator settings and send Survey Measurements

The settings on the MRX SG Marker locator should be correct, but it is worth checking the following settings:

  1. Ensure your paired device is switched on and running a compatible app, for Android or iOS.
  2. Check phone type is set correctly: MENU > PHONE > IOS to select for iOS devices or MENU > PHONE > ANDRD > BT to select for Android devices.
  3. Check SMLOG COM is ON: MENU > SMLOG > COM > ON.
  4. Check SMLOG PROT is set to ASCII 2: MENU: SMLOG > PROT > ASCII > 2.
  5. Check GPS is ON: MENU > SMLOG > PROT > ASCII > GPS+ > YES.
  6. Check RTK is ON: MENU > GPS > RTK > ON.
  7. Check MAG_H is ON: MENU > INFO > MAG-H > ON.
  8. Press the Survey key to store and send Survey Measurement to external device.

Erasing Survey Measurements

MRX SG Marker locator allows you to delete all Survey Measurements.

Erasing the log will wipe the MRX SG Marker locator memory but is usually recommended when you begin a new survey.

NOTE: Erasing Survey Measurements cannot be undone.

  1. Set DATA to DEL: SMLOG > DATA > DEL > YES.