Keypad actions

Follow Avatar Anthony Caplin
Updated : Created :
In this article

Power on /off

Switch the locator or transmitter on by pressing the key.

To switch the locator or transmitter off, press and hold the key until the screen blanks off.

NOTE: The locator will automatically power off after 5 minutes if no keys are pressed.

 

Keypad actions & shortcuts

 

Locator key actions 

Key Short press Long press
Enter the menu. Switch power off.

Scroll through locate frequencies from low to high.

In active locating: SideStep 
When using Current Direction™:
Perform a CD Reset

When using active frequencies: Toggle Peak, Peak+, Null and Guidance antenna modes.

In Power Mode: scroll through Power Filters™ for improved discrimination of parallel or strong power signals.

With the loop folded down: toggles marker and combined (marker/line) modes.

In Peak+ antenna mode:

Switch between Guidance and Null arrows.

 

 

 

Increase and decrease gain. RD8100 automatically sets gain to mid-point when pressed.

With the loop folded down only, affects the marker locator gain.

Rapidly increase and decrease gain steps in 1dB increments.
mceclip1.png

Send a survey measurement over Bluetooth if paired.

 
mceclip2.png Send an iLOC command to a paired transmitter Enter the transmitter power setting menu for use over iLOC

 

Transmitter key actions 

Key Short press Long press
Enter the menu. Switch power off.
Scroll through locate frequencies from low to high.  
Take voltage and impedance measurements using selected frequency. Take voltage and impedance measurements at a standardized frequency.
Adjusts the output signal. Select standby /maximum standard power.

 

NOTE: to scroll through frequencies from high to low, holdwhile pressing the button (applies to both locators and transmitters).

 

Antenna modes

The RD8100 locator supports 7 cable, pipe and marker locate modes, each of which is designed for specific uses, depending on what task is being carried out.

 

To scroll between locate modes, press thekey.

 

PEAK: For accurate locating, the peak bargraph provides a visual readout of the signal strength. The peak signal is found directly over the buried utility.
PEAK+: Choose to combine the accuracy of the peak bargraph with Null arrows, which can indicate the presence of distortion, or with proportional Guidance arrows for rapid line tracing - switch between them by pressing and holding the key.
GUIDANCE: Proportional arrows and a ballistic directional 'needle' combine with audio left/right indication for rapidly tracing the general path of a buried utility.
mceclip0.png BROAD PEAK: Operating similarly to Peak mode, but giving a result over a wider area. Used to detect and trace very weak signals, for example very deep utilities.
NULL: Provides a quick left/right indication of the path of a utility. As Null is susceptible to interference, it is best used in areas where no other utilities are present.
mceclip0.png

MARKER: Selected by lowering the antenna loop down, is used to locate a specific marker

mceclip1.png COMBINED MODE: Selected by lowering the antenna loop and by pressing the key, is used to locate a specific marker whilst tracing a buried utility